How to Transfer Data from Database to Snowflake

How to Transfer Data from Database to Snowflake

Open Automation Software can be used to transfer the latest database field value to a Snowflake table, locally or over a network. Rows are written continuously using the Snowpipe Streaming REST API, with no staging files, no COPY INTO job and no warehouse running for ingestion.

This guide walks you through downloading and installing OAS, configuring a Database connector and a Tag to query a database field, preparing your Snowflake account, and streaming that tag into a Snowflake table.

For this guide on how to transfer data from a Database field to Snowflake you will need:

  • An SQLite database with some example data
  • An OAS installation licensed for the Snowflake option
  • A Snowflake account with Snowpipe Streaming available
  • Access to a Snowflake administrator holding ACCOUNTADMIN, to create the user, role and table

ℹ️ This guide uses an existing SQLite database with temperature data logged by OAS. You can configure a similar Data Logging configuration or you can provide your own database.

Info

Snowflake is a write-only destination for OAS. The driver streams tag data into a table and never reads back from it, so Snowflake appears as a destination in these guides and never as a source.

For the full description of every driver field, see the Snowflake Driver reference.

1 - Download and Install OAS

If you have not already done so, you will need to download and install the OAS platform.

Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows, run the downloaded setup.exe file to install the Open Automation Software platform. For a default installation, Agree to the End User License Agreement and then click the Next button on each of the installation steps until it has completed.

If you'd like to customize your installation or learn more, use the following instructions:

The OAS Service Control application will appear when the installation finishes on Windows.

OAS Service Control

Click on each START SERVICE button to start each of the three OAS services.

2 - Configure OAS

Web Configuration Application

Configuration of the OAS server is performed from the built-in Web Configuration Application. This is the main application for accessing any settings within the OAS server and is completely self-contained within the server.

OAS Logo

You can reach this by opening your browser to:

http://<your server>:58725/app/config

If you are browsing from the OAS machine itself, you can use localhost, otherwise use the IP address of the machine. You will also need to ensure port 58725 is open on both the client and the server or you may not be able to reach the application.

On a new installation the OAS engine has no accounts yet, so the first screen you see is Create Admin Account. Once the administrator account exists that screen is not shown again, and browsing to the application displays the sign in screen instead.

Create Admin Account

OAS Web Config Login

  1. Enter a name for the administrator in the Admin user name field. Typically you would use admin, but you can use whatever name you choose.

  2. Enter a password in the Password field, then enter the same password again in the Confirm password field.

  3. Click on the Create admin & sign in button. The account is created and you are signed in to the engine.

Warning

Write these credentials down and keep them safe. There is no automated password recovery. If they are lost, the administrator must be restored on the server itself.

To sign in from then on, enter the Network node of the OAS engine, then the Username and Password of your account, and click on the Sign in button.

Info

In this guide you will use the Web Configuration Application to configure the local Node which by default is localhost.

If you have installed OAS on a remote instance you can also connect to the remote instance by setting the relevant IP address or host name in the Node field.

Important

Eventually the Legacy Desktop Configuration Application will be retired, but it is currently still available and shipped with the OAS product installation. If you choose to use it, instructions for accessing it are below. Documentation in the Knowledge Base will be replaced with the Web Application when it is retired.

Legacy Configuration Application

  1. From your operating system start menu, open the Configure OAS application.

  2. Select the Configure > Tags screen.

    Important

    If this is the first time you have installed OAS, the AdminCreate utility will run when you select a screen in the Configure menu. This will ask you to create a username and password for the admin user. This user will have full permissions in the OAS platform.

    For further information see Getting Started - Security.

  3. If this is the first time you are logging in, you will see the AdminCreate utility. Follow the prompts to set up your admin account. Otherwise, select the Log In menu button and provide the Network Node, username and password.

    Log In Menu

    Log In Dialog

3 - Configure Database Data Source

In the following steps you will create and configure a Database Connector to connect to a local SQLite database file that contains example temperature data.

ℹ️ If you want to use your own database server you can select the relevant Provider and configure it according to your database server settings and credentials.

  1. Select Drivers in the sidebar.

  2. Click + Add, enter a meaningful Driver Interface Name to give this driver interface instance a unique name, and click Create. Once created, the driver interface name should appear in the list of drivers.

  3. Ensure the following parameters are configured:

    • Driver: Database
    • Provider: SQLite
    • File Path: Absolute path to your sqlite database file

    Database driver

  4. Turn on Enable and click on the Apply changes button. The driver interface is not active until it is enabled and the changes are applied.

    Apply changes button

4 - Add Data Source Tag

In this section you will create a Tag to represent your data point in the field (for example a temperature sensor). This can then be transferred your desired destination.

  1. In the sidebar menu, select Tags.

    Configure tags menu

  2. If you want to add a Tag to the root Tags group make sure another tag at the root is selected. Click the [+] button and select Add Tag.

    Add tag button

    If you want to add a Tag to a Tag Group, select the Tag Group first and then click on the [+] button. Alternatively, you can right click on a Tag Group and select Add Tag.

    You can also add Tag Groups by clicking the [+] and selecting Add Group.

  3. Provide a Tag Name such as TemperatureSensor and click the Create button.

    Add tag to root node dialog

5 - Assign Database as Tag Data Source

You will now set the Tag's data source to the Database driver interface that you created previously.

Tips

When configuring the Database data source it is important to remember that this connector is designed to return a single field from the first row that is returned based on the following criteria:

  • Table or View name (required)
  • Field Name (required)
  • Where clause (optional)
  • Order By clause (optional)

You can use the WHERE and ORDER BY clauses to control which rows are returned. This can be any standard syntax supported by your database provider. Even if more than one row is returned by the query, OAS will only look at the first row.

The following shows an example SQLite database table:

Database Tag configuration

  1. Select the Tag that will source data from a Database data source.

    Tag

  2. Set the Data Source to Database.

  3. Set the Select Driver Interface drop-down to the Database Connector interface created previously.

  4. Set the Table or View field to the name of the table or view in the database that contains your data value.

  5. Set the Field Name field to the name of the column in the table that contains your data value.

  6. To ensure you only get the latest value, set the Order By String to DateAndTime DESC. Note that DateAndTime in this case is the standard column name that OAS logs when using the data logging feature. If your data has a different column name you can use yours instead.

    Database Tag configuration

  7. Click on the Apply changes button to apply the changes.

  8. Check that the quality status is Good and the Tag value is as expected.

    Tag

6 - Prepare Your Snowflake Account

Snowflake is a hosted service, so it has to be prepared before OAS can write to it. These steps are performed in Snowflake, by a Snowflake administrator. OAS does not browse or create objects in your account.

Important

The names used below are examples. Substitute your own, and keep them consistent — the grants have to name the same objects the driver is pointed at.

Example nameWhat it is
abcdefg-xy12345The account identifier. Yours will be different, and using this one will fail
OAS_SVCThe Snowflake user the driver authenticates as
OAS_STREAM_ROLEThe role holding the grants
OAS_DB / OAS_DATA / OAS_TAG_VALUESThe database, schema and table the rows are written to
  1. Find your account identifier. It is the whole subdomain of your Snowflake URL — everything before .snowflakecomputing.com. In Snowsight, go to Admin > Accounts, open the ... menu on your account and choose Manage URLs.

    Important

    Do not use the LOCATOR column on the Accounts page. It looks like an identifier, it is right there on screen, and it does not work — authentication fails with a bare 401 that explains nothing.

  2. Create a user and a role in a Snowsight worksheet, as ACCOUNTADMIN.

    CREATE ROLE  IF NOT EXISTS OAS_STREAM_ROLE;
    CREATE USER  IF NOT EXISTS OAS_SVC
        DEFAULT_ROLE = OAS_STREAM_ROLE
        MUST_CHANGE_PASSWORD = FALSE;
    
    GRANT ROLE OAS_STREAM_ROLE TO USER OAS_SVC;
    ALTER USER OAS_SVC SET TYPE = SERVICE;
    

    Info

    If you already have a service user and role for OAS, skip this and use them. Nothing here is specific to this driver — any user whose default role holds the grants below will work. Note the user name for the driver's User field and move on.

    The driver never sends a role. The role that applies is the user's default role, which is why it is set above.

  3. Create the target table.

    CREATE DATABASE IF NOT EXISTS OAS_DB;
    CREATE SCHEMA   IF NOT EXISTS OAS_DB.OAS_DATA;
    
    CREATE TABLE IF NOT EXISTS OAS_DB.OAS_DATA.OAS_TAG_VALUES (
        id         STRING,
        value      VARIANT,
        quality    BOOLEAN,
        timestamp  TIMESTAMP_NTZ
    );
    

    These four columns match the driver's built-in Default column mapping, so a table created this way streams with no mapping work at all. If the table already exists, leave it alone and make the column mapping match its columns instead.

  4. Grant the role its privileges.

    GRANT USAGE  ON DATABASE OAS_DB                         TO ROLE OAS_STREAM_ROLE;
    GRANT USAGE  ON SCHEMA   OAS_DB.OAS_DATA                TO ROLE OAS_STREAM_ROLE;
    GRANT INSERT ON TABLE    OAS_DB.OAS_DATA.OAS_TAG_VALUES TO ROLE OAS_STREAM_ROLE;
    

    Info

    Those three grants are the entire permission surface for streaming. No warehouse, no CREATE PIPE, no OPERATE, and the driver never issues DROP or ALTER.

7 - Configure Snowflake Driver

In the following steps you will create and configure a Snowflake Driver. This driver streams the Tags you select into the table you created in the previous step. All screenshots and options in this guide will be using the built-in OAS Web Configuration interface.

  1. Log into the interface using the credential created after installing OAS. The application can be found by opening your browser to the address of your OAS installation. If you are accessing it from the machine running OAS, just use localhost, otherwise the IP address of the server:

    http://<server address>:58725/app/config

    Configure Login

  2. In the sidebar menu, select Drivers.

    Configure drivers menu

  3. Click + Add in the sidebar to create a new Driver, then set the Driver Interface Name to Snowflake Stream to give this driver interface instance a unique name.

    Configure drivers menu

    Info

    The driver interface name appears in system errors, in the driver log file name, and in the automatically generated Snowflake channel name. Choose something you will recognise later.

  4. Ensure the following parameters are configured:

    • Driver: Snowflake
    • Account Identifier: your account subdomain, for example abcdefg-xy12345
    • Authentication Type: Key Pair JWT
    • User: OAS_SVC

    Snowflake driver configuration

    Leave Account Host Override and Ingest Host Override blank. Snowflake assigns each account a separate host for streaming and the driver discovers it on every connect.

  5. Supply the private key. If you do not already have a key pair, click the GENERATE KEY button beside the Private Key Path field.

    Generate key dialog

    Choose whether to fill the Private Key PEM field or write a file on the engine machine, pick a key size, and optionally set a passphrase.

    Important

    OAS does not register the key in Snowflake for you. The dialog shows an ALTER USER statement with the public key already in it — copy it and run it in a Snowsight worksheet as ACCOUNTADMIN. Until you do, authentication fails.

    The statement is shown once. Copy it before closing the dialog.

    If you already have a key pair, paste the private key into Private Key PEM or point Private Key Path at the .p8 file, and fill in Private Key Passphrase if the key is encrypted.

  6. Set the target table:

    • Database: OAS_DB
    • Schema: OAS_DATA
    • Table: OAS_TAG_VALUES

    Snowflake target configuration

    Leave Pipe and Channel Name blank. Snowflake creates a default pipe for every table, and a channel name is generated from the node and driver interface names.

    Important

    Two OAS engines using the same channel name against the same pipe will disconnect each other. Leave Channel Name blank unless you have a specific reason not to.

  7. Turn on Enable, then click Apply changes to temporarily save the settings you have entered to this point. The driver interface is not active until it is enabled and the changes are applied.

8 - Test the Snowflake Connection

Before selecting Tags, confirm that OAS can authenticate. Select the Snowflake Stream driver in the list and click the TEST CONNECTION button.

Snowflake test connection

The test performs three checks in order and reports the first one that fails:

CheckWhat it proves
ConfigurationThe required fields are filled in and the account identifier is well formed
Private keyThe key parses, the passphrase is correct, and Snowflake accepts the signed token
Streaming endpointThe account has Snowpipe Streaming and the ingest host was discovered

Info

Test Connection does not touch the database, schema or table. A successful test means OAS can sign in as OAS_SVC; it does not mean the grants you applied in Snowflake are correct. Those are exercised when rows are first written.

Important

A 401 from the test almost always means one of three things: the ALTER USER statement was never run, the account identifier is wrong, or the User field does not match the Snowflake user the key was registered against.

9 - Map Tag Data to Table Columns

The column mapping decides what a row looks like. The table you created in the Prepare Your Snowflake Account section has four columns, and the driver's Default preset matches them exactly.

  1. Click the Edit… button on the Column Mapping row of the Snowflake driver configuration.

    Snowflake column mapping editor

  2. Click Use Preset and choose Default (4). Four columns appear:

    ColumnTypeSource
    idSTRINGTag Property → Tag Path
    valueVARIANTTag Property → Value, as-is
    qualityBOOLEANTag Property → Quality
    timestampTIMESTAMP_NTZTag Property → Timestamp, ISO 8601

    The other preset, ISA-95 Lite, produces 24 columns with the ISA-95 hierarchy flattened one column per level. It needs a different table, so use it only if you created the table from its SQL View.

  3. Optionally click + Metadata Columns to add PIPE_ID, CHANNEL_ID and STREAM_OFFSET. These let you prove in SQL that no rows were lost. If you add them here, add the matching columns to the Snowflake table as well.

    Info

    A preset is a starting point, not a mode. Once applied you can add, edit and remove columns freely.

  4. Click SQL View to see the CREATE TABLE statement your mapping describes. This is the same statement the driver would use, so it is worth comparing against the table you actually created.

    Snowflake column mapping editor SQL

    Important

    The mapping has to match the table. The Snowflake type dropdown drives the generated DDL only — it does not change what is sent, and changing it will not fix a value that is arriving in the wrong shape. Change the column's source for that.

    OAS never alters an existing table. If your table differs from the preset, edit the mapping to match the table rather than editing the table.

  5. Click OK to return to the driver configuration, Apply changes and then Save the driver so that it will be restored when the OAS server is ever restarted.

10 - Select the Tags to Publish

  1. On the Snowflake driver configuration, find the Tags to Publish table and add the Tag you created earlier (for example TemperatureSensor).

    Snowflake tags to publish

    Important

    Every Tag in this list is written to the same table using the same column mapping. Leaving the list empty is a configuration error, not an idle driver — the driver has nothing to send and will report it.

  2. Set Publish Type to Continuous with the Publish Interval set to the default of 10 seconds. This will ensure data will be published on the interval, whether the value changed or not.

  3. Click Enable, Apply changes and then Save the driver so that it will be restored with the OAS server is ever restarted.

11 - Verify Rows are Arriving in Snowflake

In a Snowsight worksheet, query the table:

SELECT * FROM OAS_DB.OAS_DATA.OAS_TAG_VALUES
ORDER BY TIMESTAMP DESC
LIMIT 20;

Rows normally become visible five to seven seconds after OAS sends them. That delay is Snowpipe Streaming's commit interval, not the driver waiting.

If you added the metadata columns to the mapping, you can also prove that nothing was dropped. This query returns rows only where the offset sequence skipped:

SELECT STREAM_OFFSET,
       LAG(STREAM_OFFSET) OVER (PARTITION BY PIPE_ID, CHANNEL_ID
                                ORDER BY STREAM_OFFSET) AS previous_offset
FROM   OAS_DB.OAS_DATA.OAS_TAG_VALUES
QUALIFY STREAM_OFFSET <> previous_offset + 1;

An empty result means every row the driver sent arrived exactly once.

If no rows appear at all:

SymptomLikely cause
Test Connection passes, no rowsThe role is missing INSERT on the table, or USAGE on the database or schema
Rows appear, one column always nullThat column's source in the mapping does not match the tag property you expected
Rows appear only after a restartThe Tag was not changing value — with Publish Latest Value Only off, a static Tag produces no rows
Nothing in the table, errors in the logCheck Configure > System Errors for the driver interface name Snowflake Stream

While the connection is down, values are held by Store and Forward and delivered oldest first once it recovers, so a network outage delays rows rather than losing them.

12 - Save Changes

Once you have successfully configured your OAS instances, make sure you save your configuration.

On each configuration page that has a Save button, click on it.

If this is the first time you are saving the configuration, or if you are changing the name of the configuration file, OAS will ask you if you want to change the default configuration file.

If you select Yes then OAS will make this configuration file the default and if the OAS service is restarted then this file will be loaded on start-up.

If you select No then OAS will still save your configuration file, but it will not be the default file that is loaded on start-up.

Important

Each configuration screen has an independent configuration file except for the Tags and Drivers configurations, which share the same configuration file. It is still important to click on the Save button whenever you make any changes on those screens.

The Security, Users and Options screens have no Save button. Changes you make there are written to disk as soon as you make them, so there is nothing further to save.

For more information see: Save and Load Configuration

Info

  • On Windows the configuration files are stored in C:\ProgramData\OpenAutomationSoftware\ConfigFiles.
  • On Linux the configuration files are stored in the ConfigFiles subfolder of the OAS installation path.

Ready to get started?