How to Transfer Data from OPC UA to Kafka

Open Automation Software can be used to transfer data from an OPC UA server or device to a Kafka cluster, locally or over a network. This guide walks you through downloading and installing OAS, configuring an OPC UA connector, a tag and a Kafka publisher, and finally publishing the tag using the Kafka publisher.
For this guide on how to transfer data from an OPC UA source to a Kafka cluster you will need:
- Docker installed in Linux or Windows including the docker-compose utility
ℹ️ For simulation purposes, you will use the OPC UA server available in the OAS platform to access a Tag value. If you already have an OPC UA server or device available, you can also adjust your configuration to suit your own OPC UA server or device.
Info
If you have your own Kafka cluster deployed you can skip the steps for Docker and creating a Kafka cluster.
1 - Download and Install OAS
If you have not already done so, you will need to download and install the OAS platform.
Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.
On Windows, run the downloaded setup.exe file to install the Open Automation Software platform. For a default installation, Agree to the End User License Agreement and then click the Next button on each of the installation steps until it has completed.
If you'd like to customize your installation or learn more, use the following instructions:
The OAS Service Control application will appear when the installation finishes on Windows.

Click on each START SERVICE button to start each of the three OAS services.
2 - Configure OAS
Web Configuration Application
Configuration of the OAS server is performed from the built-in Web Configuration Application. This is the main application for accessing any settings within the OAS server and is completely self-contained within the server.

You can reach this by opening your browser to:
http://<your server>:58725/app/config
If you are browsing from the OAS machine itself, you can use localhost, otherwise use the IP address of the machine. You will also need to ensure port 58725 is open on both the client and the server or you may not be able to reach the application.
On a new installation the OAS engine has no accounts yet, so the first screen you see is Create Admin Account. Once the administrator account exists that screen is not shown again, and browsing to the application displays the sign in screen instead.


Enter a name for the administrator in the Admin user name field. Typically you would use
admin, but you can use whatever name you choose.Enter a password in the Password field, then enter the same password again in the Confirm password field.
Click on the Create admin & sign in button. The account is created and you are signed in to the engine.
Warning
Write these credentials down and keep them safe. There is no automated password recovery. If they are lost, the administrator must be restored on the server itself.
To sign in from then on, enter the Network node of the OAS engine, then the Username and Password of your account, and click on the Sign in button.
Info
In this guide you will use the Web Configuration Application to configure the local Node which by default is localhost.
If you have installed OAS on a remote instance you can also connect to the remote instance by setting the relevant IP address or host name in the Node field.
Important
Eventually the Legacy Desktop Configuration Application will be retired, but it is currently still available and shipped with the OAS product installation. If you choose to use it, instructions for accessing it are below. Documentation in the Knowledge Base will be replaced with the Web Application when it is retired.
Legacy Configuration Application
From your operating system start menu, open the Configure OAS application.
Select the Configure > Tags screen.
Important
If this is the first time you have installed OAS, the AdminCreate utility will run when you select a screen in the Configure menu. This will ask you to create a username and password for the admin user. This user will have full permissions in the OAS platform.
For further information see Getting Started - Security.
If this is the first time you are logging in, you will see the AdminCreate utility. Follow the prompts to set up your admin account. Otherwise, select the Log In menu button and provide the Network Node, username and password.


3 - Create a Kafka test cluster using Docker
In this step you will create a local Kafka cluster. To simplify the deployment you will need to have Docker installed including the docker-compose utility. This method allows you to create a cluster very quickly for testing purposes and remove it again when you are done.
Create a new folder such as Kafka and inside the folder create a new
docker-compose.ymlfile with the following definition.services: zookeeper: image: confluentinc/cp-zookeeper:latest container_name: zookeeper ports: - "2181:2181" environment: ZOOKEEPER_CLIENT_PORT: 2181 ZOOKEEPER_TICK_TIME: 2000 kafka: image: confluentinc/cp-kafka:latest container_name: kafka ports: - "9092:9092" environment: KAFKA_BROKER_ID: 1 KAFKA_ZOOKEEPER_CONNECT: zookeeper:2181 KAFKA_ADVERTISED_LISTENERS: PLAINTEXT://localhost:9092 KAFKA_LISTENER_SECURITY_PROTOCOL_MAP: PLAINTEXT:PLAINTEXT KAFKA_OFFSETS_TOPIC_REPLICATION_FACTOR: 1Open a command line or bash terminal in the Kafka folder and use the following command to start a new container. This will download the image and all its dependencies and may take a few minutes.
docker-compose up -dCreate a new topic called temperature using the following command.
docker exec kafka kafka-topics --create --topic temperature --bootstrap-server localhost:9092 --partitions 1 --replication-factor 1
Info
Once you are done testing, you can stop and remove the containers that you created by using the following command:
docker-compose down
4 - Create Security Group and User
When connecting to the local OAS OPC UA server, you need to configure a security group and a user to provide Tag read/write access. You'll need these credentials when creating the OPC UA connector instance later.
ℹ️ You can skip this step if you are connecting to your own third party OPC UA server.
Select Security in the sidebar.
Click + Add, enter a Name such as OPC UA Access and click Create. Once created, the security group name should appear in the list of security groups.

In the Tags section, ensure Get Tag Group Names and Get Tag Names are turned on. This setting is required when browsing the OPC UA server tag structure once you get to the step of assigning the OPC UA data source to a Tag.

In the Read Tags section, ensure Disable All Tags From Reading is turned off.

In the Write Tags section, ensure Disable All Tags From Writing is turned off.

Select Users in the sidebar.
Click + Add, enter a User name such as opcuauser, set a Password, set the Security group to OPC UA Access and click Create. Once created, the user name should appear in the list of users.

5 - Add Simulated OPC UA Tag for Temperature Sensor
In this section you will create a Tag to represent a Temperature sensor that will then be read from the OAS OPC UA server. This represents a temperature output from your source OPC UA server. This Tag is used for simulation because we are using the OAS OPC UA server.
ℹ️ If you have your own third-party OPC UA server where you can simulate a Tag value then you can skip this step.
Select Tags in the sidebar.
Make sure no Tag Group is selected and click on the + button, then choose Add tag.

Provide a Tag Name such as OPCUA_TemperatureOutput and click the Create button.

In the Enter Value field enter a value to represent the simulated temperature and then click on the Apply changes button.

6 - Configure OPC UA Data Source
In the following steps you will create and configure a OPC UA Connector to connect to the OAS internal OPC UA server on port 58728 and act as a data source.
ℹ️ If you want to use your own third-party OPC UA server you can provide the relevant Server URL and security credentials instead of the details provided below.
Select Drivers in the sidebar.
Click + Add, enter a meaningful Driver Interface Name to give this driver interface instance a unique name, and click Create. Once created, the driver interface name should appear in the list of drivers.
Ensure the following parameters are configured:
- Driver: OPC UA
- Server Url: opc.tcp://localhost:58728
Click on the Browse… button next to the Security Profile field. In the Security Profile window choose the appropriate security profile. For this guide we will choose None:None:Binary, then click on the Use this profile button.

Set Authentication to Username and enter the Username and Password credentials created in the earlier section.

Turn on Enable and click on the Apply changes button. The driver interface is not active until it is enabled and the changes are applied.

7 - Add Data Source Tag
In this section you will create a Tag to represent your data point in the field (for example a temperature sensor). This can then be transferred your desired destination.
In the sidebar menu, select
Tags.
If you want to add a Tag to the root Tags group make sure another tag at the root is selected. Click the
[+]button and select Add Tag.
If you want to add a Tag to a Tag Group, select the Tag Group first and then click on the
[+]button. Alternatively, you can right click on a Tag Group and select Add Tag.You can also add Tag Groups by clicking the
[+]and selecting Add Group.Provide a Tag Name such as TemperatureSensor and click the Create button.

8 - Assign OPC UA as Tag Data Source
You will now set the Tag's data source to the OPC UA driver interface that you created previously to act as a data source.
Select the Tag that will source data from the local OPC UA data source.

Set the Data Source to OPC UA.
Set the Select Driver Interface drop-down to the OPC UA Connector interface created previously.
Click on the Browse… button next to the NodeId field. The Browse for Node ID window lists the nodes available on the OPC UA server that the driver interface is connected to.

Expand the Local node, expand OPCUA_TemperatureOutput, and select Value, so that the NodeId reads OPCUA_TemperatureOutput.Value. Click on the Use this node button to select this node.
Click on the Apply changes button to apply the changes.

Check that the quality status is Good and the Tag value is as expected.

If you change the value of the OPCUA_TemperatureOutput Tag then you should see the same value update in the TemperatureSensor Tag. This means your OPC UA interface is working.
9 - Configure Kafka Producer
In the following steps you will create and configure a Kafka Connector connecting to a local Kafka cluster on port 9092. This connector will act as a Producer where Tags are published to a topic in the cluster.
Select Drivers in the sidebar.
Click + Add, enter a meaningful Driver Interface Name to give this driver interface instance a unique name (for example Kafka Producer), and click Create. Once created, the driver interface name should appear in the list of drivers.
Ensure the following parameters are configured:
- Driver: Kafka
- Bootstrap Servers: localhost:9092
- Security Protocol: Plaintext
- Client Id: oas-kafka-producer

The app flags the Bootstrap Servers field because it is still the default
localhost:9092. That is the address of the local test cluster you created, so leave it as it is. Change it if your broker is on another host or port.Turn on Enable and click on the Apply changes button. The driver interface is not active until it is enabled and the changes are applied.

10 - Publish Selected Tags in Kafka Producer
In this step you will select the Tags that you want to publish to the Kafka cluster.
In the Drivers screen, select the Kafka driver instance that you created in the previous section (for example Kafka Producer).
Make sure the Publish Selected Tags toggle is turned on.

In the Tags To Publish table click on the Add button.

The Publish tag window will appear. Click on the … button to browse for a Tag, select the Tag you want to add in the left hand panel and then ensure the Value property is selected, and click on the Use this tag button.

Back in the Publish tag window the Id defaults to the full Tag path (e.g. TemperatureSensor.Value). If you want to set your own property name, you can change the Id field to your own custom value. Click on the OK button.

The Tag has now been added to the list. You can add other Tags by repeating steps 3 to 5.

Click on the Apply changes button.
11 - Verify Messages are Published to Kafka Cluster
In this step you will confirm that OAS is successfully publishing your selected Tags to the Kafka cluster.
Run the following command in a terminal or command line window to start listening for new messages on the oas_tags topic which is the default topic for the Publish Selected Tags configuration.
docker exec kafka kafka-console-consumer --topic oas_tags --bootstrap-server localhost:9092Info
You may receive a warning message, because the oas_tags topic doesn't exist yet. You can safely ignore this as it will be created automatically.
Any changes your TemperatureSensor tag value should be published within 10 seconds to the terminal window.
{ "values": [ { "id": "TemperatureSensor", "value": 24.902344, "quality": true, "timestamp": "2025-05-20T09:23:41.332Z" } ] }To stop listening for new messages press the Ctrl-C shortcut combination on your keyboard.
12 - Save Changes
Once you have successfully configured your OAS instances, make sure you save your configuration.
On each configuration page that has a Save button, click on it.
If this is the first time you are saving the configuration, or if you are changing the name of the configuration file, OAS will ask you if you want to change the default configuration file.
If you select Yes then OAS will make this configuration file the default and if the OAS service is restarted then this file will be loaded on start-up.
If you select No then OAS will still save your configuration file, but it will not be the default file that is loaded on start-up.
Important
Each configuration screen has an independent configuration file except for the Tags and Drivers configurations, which share the same configuration file. It is still important to click on the Save button whenever you make any changes on those screens.
The Security, Users and Options screens have no Save button. Changes you make there are written to disk as soon as you make them, so there is nothing further to save.
For more information see: Save and Load Configuration
Info
- On Windows the configuration files are stored in C:\ProgramData\OpenAutomationSoftware\ConfigFiles.
- On Linux the configuration files are stored in the ConfigFiles subfolder of the OAS installation path.
Ready to get started?