How to Transfer Data from Allen Bradley to Azure IoT

How to Transfer Data from Allen Bradley to Azure IoT


Open Automation Software can be used to transfer data from Allen Bradley ControlLogix, CompactLogix, GuardLogix, Micro800 MicroLogix, SLC 500, and PLC-5 controllers to Azure IoT, locally or over a network.  This tutorial walks you through downloading and installing OAS, configuring an Allen Bradley and an Azure IoT driver, configuring Allen Bradley and Azure IoT tags and implementing Data Route.

Step 1. Download and Install the Open Automation Software and Start the OAS Service

If you have not already done so, you will need to download and install the OAS platform.  Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows run the downloaded Setup.exe file to install one or more of the Open Automation Software features. Select the default Typical installation if you are not sure what features to use or the Custom installation if you want to save disk space on the target system.  When prompted agree to the End User License Agreement to continue the installation.

For more detailed instructions and video tutorials, visit the installation guide for your system:
Windows Installation | Linux Installation | Raspberry Pi Installation | Dockers Installation

The OAS Service Control application will appear when the installation finishes on Windows.  Use this application to start the 3 Services. Run the Configure OAS application on Windows and select Configure-Tags; if the first time running, the AdminCreate utility will run to create an Administrator login as shown in Step 1 of Getting Started – Security.


Step 2. Configure Your Allen Bradley Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.

  2. Select Configure >> License from the top menu and verify that Allen Bradley is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Allen Bradley available, contact support@openautomationsoftware.com to update your license.

  3. Select Configure >> Drivers from the top menu.


  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.


  5. The Configure Drivers Screen will appear. Select either AB Classic for MicroLogix, SLC 500, and PLC-5 or AB Logic for ControlLogix, CompactLogix, GuardLogix, and Micro800 from the Driver dropdown box.


  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Allen Bradley Data Source.

  7. Define the properties for the desired physical connection.

  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Allen Bradley data source, click here to see our Getting Started Allen Bradley tutorial.


Step 3. Configure Your Azure IoT Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.

  2. Select Configure >> License from the top menu and verify that Azure IoT is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Azure IoT available, contact support@openautomationsoftware.com to update your license.

  3. Select Configure >> Drivers from the top menu.


  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.


  5. The Configure Drivers Screen will appear. Select Azure IoT from the Driver dropdown box.


  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Azure IoT Data Source.

  7. Enter the Azure IoT Device ID you want to use.

  8. Enter the Azure IoT Connection.

  9. Enter the Azure IoT Hub URL.

  10. Select the preferred Azure IoT Transport. Typically it is AMQP.

  11. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Azure IoT data source, visit our Getting Started Azure Iot Data Hub tutorial or watch the video tutorial below:


Step 4. Configure Your Allen Bradley Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.


  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.


  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.


  4. A dialog box will appear. Enter a name for your new tag and click ok.

  5. A configuration screen will appear for your new tag. Select your data source type in in the Data Source dropdown box.


  6. Specify the correct data type in the Data Type dropdown box.

  7. Click Apply Changes at the bottom right of the window.

For more detailed instructions on configuring your tags, click here to see our Getting Started Tags tutorial.


Step 5. Repeat Step 4 with Your Azure IoT Tags

Step 6. Configure the Target Tab of the Source Tags

  1. Select one of your source tags.

  2. Select it’s Target tab.


  3. Enable Write to Target

  4. Select the Target Type (Tag, OPC, Azure IoT, Azure IoT Edge, or MQTT) from the dropdown.

  5. Select the destination for the value to be sent. If Tag is selected then select Browse and select the desired tag from the localhost system or optionally a remote system for transfer over a network.



    Local: TagName.Value

    Remote: \\192.168.0.1\TagName.Value

    If OPC Item is selected select browse and select the OPC Server and Item



    If Azure IoT is selected then select the Driver Interface.



    If MQTT is selected then select the Driver Interface and Topic.




  6. Enter the desired float value Deadband field. Enter 0 for no deadband.

  7. If you want to specify a desired update frequency for the target check Write Continuously and enter the desired frequency. If Write Contentiously is unchecked the the target will be updated every time the source tag changes.

  8. Click the Apply Changes button to save your changes.

  9. Repeat this step for each tag that you want to transfer data from. This can also be done in bulk with CSV Import/Export or programatically.

For more detailed instructions on Configuring Data Route functionality, visit our Getting Started – Data Route tutorial or watch the videos below:

Multiple Tag Transfer

Tag to Tag Transfer

IoT Publish


How to Transfer Data from AWS IoT to Allen Bradley

How to Transfer Data from AWS IoT to Allen Bradley

Open Automation Software can be used to transfer data from an AWS IoT Gateway to Allen Bradley ControlLogix, CompactLogix, GuardLogix, Micro800 MicroLogix, SLC 500, and PLC-5 controllers, locally or over a network.  This tutorial walks you through downloading and installing OAS, configuring an AWS IoT and an Allen Bradley driver, configuring AWS and Allen Bradley tags and implementing Data Route.

Step 1. Download and Install the Open Automation Software and Start the OAS Service

If you have not already done so, you will need to download and install the OAS platform.  Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows run the downloaded Setup.exe file to install one or more of the Open Automation Software features. Select the default Typical installation if you are not sure what features to use or the Custom installation if you want to save disk space on the target system.  When prompted agree to the End User License Agreement to continue the installation.

For more detailed instructions and video tutorials, visit the installation guide for your system:
Windows Installation | Linux Installation | Raspberry Pi Installation | Dockers Installation

The OAS Service Control application will appear when the installation finishes on Windows.  Use this application to start the 3 Services. Run the Configure OAS application on Windows and select Configure-Tags; if the first time running, the AdminCreate utility will run to create an Administrator login as shown in Step 1 of Getting Started – Security.


Step 2. Configure Your AWS IoT Gateway Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that AWS IoT is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see AWS IoT available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select AWS IoT Gateway from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an AWS IoT Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your AWS IoT Gateway data source, click here to see our Getting Started AWS IoT Gateway tutorial.


Step 3. Configure Your Allen Bradley Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that Allen Bradley is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Allen Bradley available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select either AB Classic for MicroLogix, SLC 500, and PLC-5 or AB Logic for ControlLogix, CompactLogix, GuardLogix, and Micro800 from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Allen Bradley Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Allen Bradley data source, click here to see our Getting Started Allen Bradley tutorial.


Step 4. Configure Your AWS Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select your data source type in in the Data Source dropdown box.

  6. Specify the correct data type in the Data Type dropdown box.
  7. Click Apply Changes at the bottom right of the window.

For more detailed instructions on configuring your tags, click here to see our Getting Started Tags tutorial.


Step 5. Repeat Step 4 with Your Allen Bradley Tags

Step 6. Configure the Target Tab of the Source Tags

  1. Select one of your source tags.
  2. Select it’s Target tab.

  3. Enable Write to Target
  4. Select the Target Type (Tag, OPC, Azure IoT, Azure IoT Edge, or MQTT) from the dropdown.
  5. Select the destination for the value to be sent.
    If Tag is selected then select Browse and select the desired tag from the localhost system or optionally a remote system for transfer over a network.

    Local: TagName.Value

    Remote: \\192.168.0.1\TagName.Value

    If OPC Item is selected select browse and select the OPC Server and Item

    If Azure IoT is selected then select the Driver Interface.

    If MQTT is selected then select the Driver Interface and Topic.

  6. Enter the desired float value Deadband field. Enter 0 for no deadband.
  7. If you want to specify a desired update frequency for the target check Write Continuously and enter the desired frequency. If Write Contentiously is unchecked the the target will be updated every time the source tag changes.
  8. Click the Apply Changes button to save your changes.
  9. Repeat this step for each tag that you want to transfer data from. This can also be done in bulk with CSV Import/Export or programatically.

For more detailed instructions on Configuring Data Route functionality, visit our Getting Started – Data Route tutorial or watch the videos below:

Multiple Tag Transfer

Tag to Tag Transfer

IoT Publish


How to Transfer Data from Allen Bradley to AWS IoT

How to Transfer Data from Allen Bradley to AWS IoT
How to Transfer Data from Allen Bradley to AWS IoT

Open Automation Software can be used to transfer data from Allen Bradley ControlLogix, CompactLogix, GuardLogix, Micro800 MicroLogix, SLC 500, and PLC-5 controllers to an AWS IoT Gateway, locally or over a network.  This tutorial walks you through downloading and installing OAS, configuring an Allen Bradley and an AWS IoT driver, configuring Allen Bradley and AWS tags and implementing Data Route.

Step 1. Download and Install the Open Automation Software and Start the OAS Service

If you have not already done so, you will need to download and install the OAS platform.  Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows run the downloaded Setup.exe file to install one or more of the Open Automation Software features. Select the default Typical installation if you are not sure what features to use or the Custom installation if you want to save disk space on the target system.  When prompted agree to the End User License Agreement to continue the installation.

For more detailed instructions and video tutorials, visit the installation guide for your system:
Windows Installation | Linux Installation | Raspberry Pi Installation | Dockers Installation

The OAS Service Control application will appear when the installation finishes on Windows.  Use this application to start the 3 Services. Run the Configure OAS application on Windows and select Configure-Tags; if the first time running, the AdminCreate utility will run to create an Administrator login as shown in Step 1 of Getting Started – Security.


Step 2. Configure Your Allen Bradley Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that Allen Bradley is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Allen Bradley available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select either AB Classic for MicroLogix, SLC 500, and PLC-5 or AB Logic for ControlLogix, CompactLogix, GuardLogix, and Micro800 from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Allen Bradley Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Allen Bradley data source, click here to see our Getting Started Allen Bradley tutorial.


Step 3. Configure Your AWS IoT Gateway Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that AWS IoT is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see AWS IoT available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select AWS IoT Gateway from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an AWS IoT Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your AWS IoT Gateway data source, click here to see our Getting Started AWS IoT Gateway tutorial.


Step 4. Configure Your Allen Bradley Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select your data source type in in the Data Source dropdown box.

  6. Specify the correct data type in the Data Type dropdown box.
  7. Click Apply Changes at the bottom right of the window.

For more detailed instructions on configuring your tags, click here to see our Getting Started Tags tutorial.


Step 5. Repeat Step 4 with Your AWS Tags

Step 6. Configure the Target Tab of the Source Tags

  1. Select one of your source tags.
  2. Select it’s Target tab.

  3. Enable Write to Target
  4. Select the Target Type (Tag, OPC, Azure IoT, Azure IoT Edge, or MQTT) from the dropdown.
  5. Select the destination for the value to be sent.
    If Tag is selected then select Browse and select the desired tag from the localhost system or optionally a remote system for transfer over a network.

    Local: TagName.Value

    Remote: \\192.168.0.1\TagName.Value

    If OPC Item is selected select browse and select the OPC Server and Item

    If Azure IoT is selected then select the Driver Interface.

    If MQTT is selected then select the Driver Interface and Topic.

  6. Enter the desired float value Deadband field. Enter 0 for no deadband.
  7. If you want to specify a desired update frequency for the target check Write Continuously and enter the desired frequency. If Write Contentiously is unchecked the the target will be updated every time the source tag changes.
  8. Click the Apply Changes button to save your changes.
  9. Repeat this step for each tag that you want to transfer data from. This can also be done in bulk with CSV Import/Export or programatically.

For more detailed instructions on Configuring Data Route functionality, visit our Getting Started – Data Route tutorial or watch the videos below:

Multiple Tag Transfer

Tag to Tag Transfer

IoT Publish


How to Transfer Data from OPC to Allen Bradley

How to Transfer Data from OPC to Allen Bradley

Open Automation Software can be used to transfer data from an OPC Server to Allen Bradley ControlLogix, CompactLogix, GuardLogix, Micro800 MicroLogix, SLC 500, and PLC-5 controllers, locally or over a network.  This tutorial walks you through downloading and installing OAS, configuring an Allen Bradley driver, configuring Allen Bradley and OPC server tags and implementing Data Route.

Step 1. Download and Install the Open Automation Software and Start the OAS Service

If you have not already done so, you will need to download and install the OAS platform.  Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows run the downloaded Setup.exe file to install one or more of the Open Automation Software features. Select the default Typical installation if you are not sure what features to use or the Custom installation if you want to save disk space on the target system.  When prompted agree to the End User License Agreement to continue the installation.

For more detailed instructions and video tutorials, visit the installation guide for your system:
Windows Installation | Linux Installation | Raspberry Pi Installation | Dockers Installation

The OAS Service Control application will appear when the installation finishes on Windows.  Use this application to start the 3 Services. Run the Configure OAS application on Windows and select Configure-Tags; if the first time running, the AdminCreate utility will run to create an Administrator login as shown in Step 1 of Getting Started – Security.


Step 2. Configure OPC Server Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select OPC in the Data Source dropdown box.

  6. Use the Browse button to the right of the OPC Item to browse OPC Servers for the desired OPC Item.

  7. Select Local, the desired OPC Server, branch within the OPC Server, and OPC Item and click OK.

  8. Specify the desired OPC Update Rate for the Tag.
  9. Click Apply Changes at the bottom right of the window.

To add Tags with One Click OPC:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. To begin the One Click OPC process select the Group you would like to import to in the Tag configuration. If you want to import to the Root Level, select the Tags Group at the top of the tree.
    Then select the One Click Import button on the top menu bar.

  4. Click on the Import OPC DA 2.XX or 3.0 Items Button in the pop up window.

  5. Use the One Click OPC Wizard to browse for a branch as a starting position within an OPC Server or just select the OPC Server name itself to add all items from the selected OPC Server. For the best networking design select OPC Servers from Local even if you are configuring a remote OAS Service.

  6. Select to enable the options to Get Data Type from OPC Server and optionally the Descriptions.
    Additionally if you want to specify to Trend all of the points select Trend Points.
  7. Click Add Tags and it will automatically add all of the OPC Items from the OPC Server Branch you have selected and all of the sub Branches beneath it.
  8. Select the Save button on the toolbar at the top.

For more detailed instructions on Configuring OPC Server Tags, visit our Getting Started OPC tutorial or the One Click OPC tutorial or watch the video tutorial below:


Step 3. Configure Your Allen Bradley Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that Allen Bradley is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Allen Bradley available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select either AB Classic for MicroLogix, SLC 500, and PLC-5 or AB Logic for ControlLogix, CompactLogix, GuardLogix, and Micro800 from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Allen Bradley Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Allen Bradley data source, click here to see our Getting Started Allen Bradley tutorial.


Step 4. Configure Your Allen Bradley Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select your data source type in in the Data Source dropdown box.

  6. Specify the correct data type in the Data Type dropdown box.
  7. Click Apply Changes at the bottom right of the window.

For more detailed instructions on configuring your tags, click here to see our Getting Started Tags tutorial.


Step 5. Configure the Target Tab of the Source Tags

  1. Select one of your source tags.
  2. Select it’s Target tab.

  3. Enable Write to Target
  4. Select the Target Type (Tag, OPC, Azure IoT, Azure IoT Edge, or MQTT) from the dropdown.
  5. Select the destination for the value to be sent.
    If Tag is selected then select Browse and select the desired tag from the localhost system or optionally a remote system for transfer over a network.

    Local: TagName.Value

    Remote: \\192.168.0.1\TagName.Value

    If OPC Item is selected select browse and select the OPC Server and Item

    If Azure IoT is selected then select the Driver Interface.

    If MQTT is selected then select the Driver Interface and Topic.

  6. Enter the desired float value Deadband field. Enter 0 for no deadband.
  7. If you want to specify a desired update frequency for the target check Write Continuously and enter the desired frequency. If Write Contentiously is unchecked the the target will be updated every time the source tag changes.
  8. Click the Apply Changes button to save your changes.
  9. Repeat this step for each tag that you want to transfer data from. This can also be done in bulk with CSV Import/Export or programatically.

For more detailed instructions on Configuring Data Route functionality, visit our Getting Started – Data Route tutorial or watch the videos below:

Multiple Tag Transfer

Tag to Tag Transfer

IoT Publish


How to Transfer Data from Allen Bradley to OPC

How to Transfer Data from Allen Bradley to OPC

Open Automation Software can be used to transfer data from Allen Bradley ControlLogix, CompactLogix, GuardLogix, Micro800 MicroLogix, SLC 500, and PLC-5 controllers to OPC Servers, locally or over a network.  This tutorial walks you through downloading and installing OAS, configuring an Allen Bradley driver, configuring Allen Bradley and OPC tags and implementing Data Route.

Step 1. Download and Install the Open Automation Software and Start the OAS Service

If you have not already done so, you will need to download and install the OAS platform.  Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows run the downloaded Setup.exe file to install one or more of the Open Automation Software features. Select the default Typical installation if you are not sure what features to use or the Custom installation if you want to save disk space on the target system.  When prompted agree to the End User License Agreement to continue the installation.

For more detailed instructions and video tutorials, visit the installation guide for your system:
Windows Installation | Linux Installation | Raspberry Pi Installation | Dockers Installation

The OAS Service Control application will appear when the installation finishes on Windows.  Use this application to start the 3 Services. Run the Configure OAS application on Windows and select Configure-Tags; if the first time running, the AdminCreate utility will run to create an Administrator login as shown in Step 1 of Getting Started – Security.


Step 2. Configure Your Allen Bradley Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that Allen Bradley is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Allen Bradley available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select either AB Classic for MicroLogix, SLC 500, and PLC-5 or AB Logic for ControlLogix, CompactLogix, GuardLogix, and Micro800 from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Allen Bradley Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Allen Bradley data source, click here to see our Getting Started Allen Bradley tutorial.


Step 3. Configure Your Allen Bradley Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select your data source type in in the Data Source dropdown box.

  6. Specify the correct data type in the Data Type dropdown box.
  7. Click Apply Changes at the bottom right of the window.

For more detailed instructions on configuring your tags, click here to see our Getting Started Tags tutorial.


Step 4. Configure OPC Server Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select OPC in the Data Source dropdown box.

  6. Use the Browse button to the right of the OPC Item to browse OPC Servers for the desired OPC Item.

  7. Select Local, the desired OPC Server, branch within the OPC Server, and OPC Item and click OK.

  8. Specify the desired OPC Update Rate for the Tag.
  9. Click Apply Changes at the bottom right of the window.

To add Tags with One Click OPC:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. To begin the One Click OPC process select the Group you would like to import to in the Tag configuration. If you want to import to the Root Level, select the Tags Group at the top of the tree.
    Then select the One Click Import button on the top menu bar.

  4. Click on the Import OPC DA 2.XX or 3.0 Items Button in the pop up window.

  5. Use the One Click OPC Wizard to browse for a branch as a starting position within an OPC Server or just select the OPC Server name itself to add all items from the selected OPC Server. For the best networking design select OPC Servers from Local even if you are configuring a remote OAS Service.

  6. Select to enable the options to Get Data Type from OPC Server and optionally the Descriptions.
    Additionally if you want to specify to Trend all of the points select Trend Points.
  7. Click Add Tags and it will automatically add all of the OPC Items from the OPC Server Branch you have selected and all of the sub Branches beneath it.
  8. Select the Save button on the toolbar at the top.

For more detailed instructions on Configuring OPC Server Tags, visit our Getting Started OPC tutorial or the One Click OPC tutorial or watch the video tutorial below:


Step 5. Configure the Target Tab of the Source Tags

  1. Select one of your source tags.
  2. Select it’s Target tab.

  3. Enable Write to Target
  4. Select the Target Type (Tag, OPC, Azure IoT, Azure IoT Edge, or MQTT) from the dropdown.
  5. Select the destination for the value to be sent.
    If Tag is selected then select Browse and select the desired tag from the localhost system or optionally a remote system for transfer over a network.

    Local: TagName.Value

    Remote: \\192.168.0.1\TagName.Value

    If OPC Item is selected select browse and select the OPC Server and Item

    If Azure IoT is selected then select the Driver Interface.

    If MQTT is selected then select the Driver Interface and Topic.

  6. Enter the desired float value Deadband field. Enter 0 for no deadband.
  7. If you want to specify a desired update frequency for the target check Write Continuously and enter the desired frequency. If Write Contentiously is unchecked the the target will be updated every time the source tag changes.
  8. Click the Apply Changes button to save your changes.
  9. Repeat this step for each tag that you want to transfer data from. This can also be done in bulk with CSV Import/Export or programatically.

For more detailed instructions on Configuring Data Route functionality, visit our Getting Started – Data Route tutorial or watch the videos below:

Multiple Tag Transfer

Tag to Tag Transfer

IoT Publish


How to Transfer Data from MQTT to Allen Bradley

How to Transfer Data from MQTT to Allen Bradley

Open Automation Software can be used to transfer data from MQTT devices to Allen Bradley ControlLogix, CompactLogix, GuardLogix, Micro800 MicroLogix, SLC 500, and PLC-5 controllers, locally or over a network.  This tutorial walks you through downloading and installing OAS, configuring an Allen Bradley and a MQTT driver, configuring Allen Bradley and MQTT tags and implementing Data Route.

Step 1. Download and Install the Open Automation Software and Start the OAS Service

If you have not already done so, you will need to download and install the OAS platform.  Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows run the downloaded Setup.exe file to install one or more of the Open Automation Software features. Select the default Typical installation if you are not sure what features to use or the Custom installation if you want to save disk space on the target system.  When prompted agree to the End User License Agreement to continue the installation.

For more detailed instructions and video tutorials, visit the installation guide for your system:
Windows Installation | Linux Installation | Raspberry Pi Installation | Dockers Installation

The OAS Service Control application will appear when the installation finishes on Windows.  Use this application to start the 3 Services. Run the Configure OAS application on Windows and select Configure-Tags; if the first time running, the AdminCreate utility will run to create an Administrator login as shown in Step 1 of Getting Started – Security.


Step 2. Configure Your MQTT Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that MQTT is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see MQTT available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select MQTT from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with a MQTT Data Source.
  7. Enter the IP Address of the broker. The default port is 1883.
  8. Enter the User Name and Password if required.
  9. Set the Keep Alive Time. The default is 60 Seconds.
  10. Set the Reconnect Time. The default 10 Seconds. If the connection to the broker is lost the Reconnect Time determines how long to wait before attempting to reconnect.

For more detailed instructions on configuring your MQTT data source, click here to see our Getting Started MQTT tutorial or watch the video tutorial below:


Step 3. Configure Your Allen Bradley Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that Allen Bradley is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Allen Bradley available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select either AB Classic for MicroLogix, SLC 500, and PLC-5 or AB Logic for ControlLogix, CompactLogix, GuardLogix, and Micro800 from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Allen Bradley Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Allen Bradley data source, click here to see our Getting Started Allen Bradley tutorial.


Step 4. Configure Your MQTT Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select your data source type in in the Data Source dropdown box.

  6. Specify the correct data type in the Data Type dropdown box.
  7. Click Apply Changes at the bottom right of the window.

For more detailed instructions on configuring your tags, click here to see our Getting Started Tags tutorial.


Step 5. Repeat Step 4 with Your Allen Bradley Tags

Step 6. Configure the Target Tab of the Source Tags

  1. Select one of your source tags.
  2. Select it’s Target tab.

  3. Enable Write to Target
  4. Select the Target Type (Tag, OPC, Azure IoT, Azure IoT Edge, or MQTT) from the dropdown.
  5. Select the destination for the value to be sent.
    If Tag is selected then select Browse and select the desired tag from the localhost system or optionally a remote system for transfer over a network.

    Local: TagName.Value

    Remote: \\192.168.0.1\TagName.Value

    If OPC Item is selected select browse and select the OPC Server and Item

    If Azure IoT is selected then select the Driver Interface.

    If MQTT is selected then select the Driver Interface and Topic.

  6. Enter the desired float value Deadband field. Enter 0 for no deadband.
  7. If you want to specify a desired update frequency for the target check Write Continuously and enter the desired frequency. If Write Contentiously is unchecked the the target will be updated every time the source tag changes.
  8. Click the Apply Changes button to save your changes.
  9. Repeat this step for each tag that you want to transfer data from. This can also be done in bulk with CSV Import/Export or programatically.

For more detailed instructions on Configuring Data Route functionality, visit our Getting Started – Data Route tutorial or watch the videos below:

Multiple Tag Transfer

Tag to Tag Transfer

IoT Publish


How to Transfer Data from Allen Bradley to MQTT

How to Transfer Data from Allen Bradley to MQTT

Open Automation Software can be used to transfer data from Allen Bradley ControlLogix, CompactLogix, GuardLogix, Micro800 MicroLogix, SLC 500, and PLC-5 controllers to MQTT devices, locally or over a network.  This tutorial walks you through downloading and installing OAS, configuring an Allen Bradley and a MQTT driver, configuring Allen Bradley and MQTT tags and implementing Data Route.

Step 1. Download and Install the Open Automation Software and Start the OAS Service

If you have not already done so, you will need to download and install the OAS platform.  Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows run the downloaded Setup.exe file to install one or more of the Open Automation Software features. Select the default Typical installation if you are not sure what features to use or the Custom installation if you want to save disk space on the target system.  When prompted agree to the End User License Agreement to continue the installation.

For more detailed instructions and video tutorials, visit the installation guide for your system:
Windows Installation | Linux Installation | Raspberry Pi Installation | Dockers Installation

The OAS Service Control application will appear when the installation finishes on Windows.  Use this application to start the 3 Services. Run the Configure OAS application on Windows and select Configure-Tags; if the first time running, the AdminCreate utility will run to create an Administrator login as shown in Step 1 of Getting Started – Security.


Step 2. Configure Your Allen Bradley Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that Allen Bradley is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Allen Bradley available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select either AB Classic for MicroLogix, SLC 500, and PLC-5 or AB Logic for ControlLogix, CompactLogix, GuardLogix, and Micro800 from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Allen Bradley Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Allen Bradley data source, click here to see our Getting Started Allen Bradley tutorial.


Step 3. Configure Your MQTT Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that MQTT is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see MQTT available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select MQTT from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with a MQTT Data Source.
  7. Enter the IP Address of the broker. The default port is 1883.
  8. Enter the User Name and Password if required.
  9. Set the Keep Alive Time. The default is 60 Seconds.
  10. Set the Reconnect Time. The default 10 Seconds. If the connection to the broker is lost the Reconnect Time determines how long to wait before attempting to reconnect.

For more detailed instructions on configuring your MQTT data source, click here to see our Getting Started MQTT tutorial or watch the video tutorial below:


Step 4. Configure Your Allen Bradley Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select your data source type in in the Data Source dropdown box.

  6. Specify the correct data type in the Data Type dropdown box.
  7. Click Apply Changes at the bottom right of the window.

For more detailed instructions on configuring your tags, click here to see our Getting Started Tags tutorial.


Step 5. Repeat Step 4 with Your MQTT Tags

Step 6. Configure the Target Tab of the Source Tags

  1. Select one of your source tags.
  2. Select it’s Target tab.

  3. Enable Write to Target
  4. Select the Target Type (Tag, OPC, Azure IoT, Azure IoT Edge, or MQTT) from the dropdown.
  5. Select the destination for the value to be sent.
    If Tag is selected then select Browse and select the desired tag from the localhost system or optionally a remote system for transfer over a network.

    Local: TagName.Value

    Remote: \\192.168.0.1\TagName.Value

    If OPC Item is selected select browse and select the OPC Server and Item

    If Azure IoT is selected then select the Driver Interface.

    If MQTT is selected then select the Driver Interface and Topic.

  6. Enter the desired float value Deadband field. Enter 0 for no deadband.
  7. If you want to specify a desired update frequency for the target check Write Continuously and enter the desired frequency. If Write Contentiously is unchecked the the target will be updated every time the source tag changes.
  8. Click the Apply Changes button to save your changes.
  9. Repeat this step for each tag that you want to transfer data from. This can also be done in bulk with CSV Import/Export or programatically.

For more detailed instructions on Configuring Data Route functionality, visit our Getting Started – Data Route tutorial or watch the videos below:

Multiple Tag Transfer

Tag to Tag Transfer

IoT Publish


How to Transfer Data from Allen Bradley to OPC UA

How to Transfer Data from Allen Bradley to OPC UA

Open Automation Software can be used to transfer data from Allen Bradley ControlLogix, CompactLogix, GuardLogix, Micro800 MicroLogix, SLC 500, and PLC-5 controllers to OPC UA servers, locally or over a network.  This tutorial walks you through downloading and installing OAS, configuring an Allen Bradley and an OPC UA driver, configuring Allen Bradley and OPC UA tags and implementing Data Route.

Step 1. Download and Install the Open Automation Software and Start the OAS Service

If you have not already done so, you will need to download and install the OAS platform.  Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows run the downloaded Setup.exe file to install one or more of the Open Automation Software features. Select the default Typical installation if you are not sure what features to use or the Custom installation if you want to save disk space on the target system.  When prompted agree to the End User License Agreement to continue the installation.

For more detailed instructions and video tutorials, visit the installation guide for your system:
Windows Installation | Linux Installation | Raspberry Pi Installation | Dockers Installation

The OAS Service Control application will appear when the installation finishes on Windows.  Use this application to start the 3 Services. Run the Configure OAS application on Windows and select Configure-Tags; if the first time running, the AdminCreate utility will run to create an Administrator login as shown in Step 1 of Getting Started – Security.


Step 2. Configure Your Allen Bradley Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that Allen Bradley is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Allen Bradley available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select either AB Classic for MicroLogix, SLC 500, and PLC-5 or AB Logic for ControlLogix, CompactLogix, GuardLogix, and Micro800 from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Allen Bradley Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Allen Bradley data source, click here to see our Getting Started Allen Bradley tutorial.


Step 3. Configure Your OPC UA Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that OPC UA is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see OPC UA available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select OPC UA from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with a OPC UA Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your OPC DA data source, click here to see our Getting Started OPC UA tutorial.


Step 4. Configure Your Allen Bradley Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select your data source type in in the Data Source dropdown box.

  6. Specify the correct data type in the Data Type dropdown box.
  7. Click Apply Changes at the bottom right of the window.

For more detailed instructions on configuring your tags, click here to see our Getting Started Tags tutorial.


Step 5. Repeat Step 4 with Your OPC UA Tags

Step 6. Configure the Target Tab of the Source Tags

  1. Select one of your source tags.
  2. Select it’s Target tab.

  3. Enable Write to Target
  4. Select the Target Type (Tag, OPC, Azure IoT, Azure IoT Edge, or MQTT) from the dropdown.
  5. Select the destination for the value to be sent.
    If Tag is selected then select Browse and select the desired tag from the localhost system or optionally a remote system for transfer over a network.

    Local: TagName.Value

    Remote: \\192.168.0.1\TagName.Value

    If OPC Item is selected select browse and select the OPC Server and Item

    If Azure IoT is selected then select the Driver Interface.

    If MQTT is selected then select the Driver Interface and Topic.

  6. Enter the desired float value Deadband field. Enter 0 for no deadband.
  7. If you want to specify a desired update frequency for the target check Write Continuously and enter the desired frequency. If Write Contentiously is unchecked the the target will be updated every time the source tag changes.
  8. Click the Apply Changes button to save your changes.
  9. Repeat this step for each tag that you want to transfer data from. This can also be done in bulk with CSV Import/Export or programatically.

For more detailed instructions on Configuring Data Route functionality, visit our Getting Started – Data Route tutorial or watch the videos below:

Multiple Tag Transfer

Tag to Tag Transfer

IoT Publish


How to Transfer Data from OPC UA to Allen Bradley

How to Transfer Data from OPC UA to Allen Bradley

Open Automation Software can be used to transfer data from OPC UA servers to Allen Bradley ControlLogix, CompactLogix, GuardLogix, Micro800 MicroLogix, SLC 500, and PLC-5 controllers, locally or over a network.  This tutorial walks you through downloading and installing OAS, configuring an OPC UA and an Allen Bradley driver, configuring OPC UA and Allen Bradley tags and implementing Data Route.

Step 1. Download and Install the Open Automation Software and Start the OAS Service

If you have not already done so, you will need to download and install the OAS platform.  Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows run the downloaded Setup.exe file to install one or more of the Open Automation Software features. Select the default Typical installation if you are not sure what features to use or the Custom installation if you want to save disk space on the target system.  When prompted agree to the End User License Agreement to continue the installation.

For more detailed instructions and video tutorials, visit the installation guide for your system:
Windows Installation | Linux Installation | Raspberry Pi Installation | Dockers Installation

The OAS Service Control application will appear when the installation finishes on Windows.  Use this application to start the 3 Services. Run the Configure OAS application on Windows and select Configure-Tags; if the first time running, the AdminCreate utility will run to create an Administrator login as shown in Step 1 of Getting Started – Security.


Step 2. Configure Your OPC UA Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that OPC UA is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see OPC UA available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select OPC UA from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with a OPC UA Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your OPC DA data source, click here to see our Getting Started OPC UA tutorial.


Step 3. Configure Your Allen Bradley Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that Allen Bradley is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Allen Bradley available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select either AB Classic for MicroLogix, SLC 500, and PLC-5 or AB Logic for ControlLogix, CompactLogix, GuardLogix, and Micro800 from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Allen Bradley Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Allen Bradley data source, click here to see our Getting Started Allen Bradley tutorial.


Step 4. Configure Your OPC UA Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select your data source type in in the Data Source dropdown box.

  6. Specify the correct data type in the Data Type dropdown box.
  7. Click Apply Changes at the bottom right of the window.

For more detailed instructions on configuring your tags, click here to see our Getting Started Tags tutorial.


Step 5. Repeat Step 4 with Your Allen Bradley Tags

Step 6. Configure the Target Tab of the Source Tags

  1. Select one of your source tags.
  2. Select it’s Target tab.

  3. Enable Write to Target
  4. Select the Target Type (Tag, OPC, Azure IoT, Azure IoT Edge, or MQTT) from the dropdown.
  5. Select the destination for the value to be sent.
    If Tag is selected then select Browse and select the desired tag from the localhost system or optionally a remote system for transfer over a network.

    Local: TagName.Value

    Remote: \\192.168.0.1\TagName.Value

    If OPC Item is selected select browse and select the OPC Server and Item

    If Azure IoT is selected then select the Driver Interface.

    If MQTT is selected then select the Driver Interface and Topic.

  6. Enter the desired float value Deadband field. Enter 0 for no deadband.
  7. If you want to specify a desired update frequency for the target check Write Continuously and enter the desired frequency. If Write Contentiously is unchecked the the target will be updated every time the source tag changes.
  8. Click the Apply Changes button to save your changes.
  9. Repeat this step for each tag that you want to transfer data from. This can also be done in bulk with CSV Import/Export or programatically.

For more detailed instructions on Configuring Data Route functionality, visit our Getting Started – Data Route tutorial or watch the videos below:

Multiple Tag Transfer

Tag to Tag Transfer

IoT Publish


How to Transfer Data from MTConnect to Allen Bradley

How to Transfer Data from MTConnect to Allen Bradley

Open Automation Software can be used to transfer data from MTConnect devices to Allen Bradley ControlLogix, CompactLogix, GuardLogix, Micro800 MicroLogix, SLC 500, and PLC-5 controllers, locally or over a network.  This tutorial walks you through downloading and installing OAS, configuring an Allen Bradley and an MTConnect driver, configuring Allen Bradley and MTConnect tags and implementing Data Route.

Step 1. Download and Install the Open Automation Software and Start the OAS Service

If you have not already done so, you will need to download and install the OAS platform.  Fully functional trial versions of the software are available for Windows, Windows IoT Core, Linux, Raspberry Pi and Docker on our downloads page.

On Windows run the downloaded Setup.exe file to install one or more of the Open Automation Software features. Select the default Typical installation if you are not sure what features to use or the Custom installation if you want to save disk space on the target system.  When prompted agree to the End User License Agreement to continue the installation.

For more detailed instructions and video tutorials, visit the installation guide for your system:
Windows Installation | Linux Installation | Raspberry Pi Installation | Dockers Installation

The OAS Service Control application will appear when the installation finishes on Windows.  Use this application to start the 3 Services. Run the Configure OAS application on Windows and select Configure-Tags; if the first time running, the AdminCreate utility will run to create an Administrator login as shown in Step 1 of Getting Started – Security.


Step 2. Configure Your MTConnect Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that MTConnect is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see MTConnect available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select MTConnect from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with a MTConnect Data Source.
  7. Leave Enable and Add Tags Automatically enabled.
  8. Specify the Live Data Url for the MTConnect stream.
  9. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your MTConnect data source, click here to see our Getting Started MTConnect tutorial or watch the video tutorial below:


Step 3. Configure Your Allen Bradley Data Source

  1. First, you will need to open the Configure OAS application from the program group Open Automation Software.
  2. Select Configure >> License from the top menu and verify that Allen Bradley is one of the available Drivers in the lower left of the form. The demo license will have this by default. If you do not see Allen Bradley available, contact support@openautomationsoftware.com to update your license.
  3. Select Configure >> Drivers from the top menu.

  4. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  5. The Configure Drivers Screen will appear. Select either AB Classic for MicroLogix, SLC 500, and PLC-5 or AB Logic for ControlLogix, CompactLogix, GuardLogix, and Micro800 from the Driver dropdown box.

  6. Enter a meaningful Driver Interface Name that you will refer to this physical connection when defining Tags with an Allen Bradley Data Source.
  7. Define the properties for the desired physical connection.
  8. Click the Add Driver button above the Driver list in the left pane to add the Driver Interface as an available selection when defining Tags in the next step.

For more detailed instructions on configuring your Allen Bradley data source, click here to see our Getting Started Allen Bradley tutorial.


Step 4. Configure Your MTConnect Tags

OAS provides multiple ways to add and define tags:

To add a Tag manually:

  1. In the OAS Configure Application, select Configure >> Tags from the top menu.

  2. Select localhost or the remote service you wish to modify with the Select button to the right of the Network Node list.

  3. Click on the Add Tag button located at the top of the Tag browser on the left portion of the screen.

  4. A dialog box will appear. Enter a name for your new tag and click ok.
  5. A configuration screen will appear for your new tag. Select your data source type in in the Data Source dropdown box.

  6. Specify the correct data type in the Data Type dropdown box.
  7. Click Apply Changes at the bottom right of the window.

For more detailed instructions on configuring your tags, click here to see our Getting Started Tags tutorial.


Step 5. Repeat Step 4 with Your Allen Bradley Tags

Step 6. Configure the Target Tab of the Source Tags

  1. Select one of your source tags.
  2. Select it’s Target tab.

  3. Enable Write to Target
  4. Select the Target Type (Tag, OPC, Azure IoT, Azure IoT Edge, or MQTT) from the dropdown.
  5. Select the destination for the value to be sent.
    If Tag is selected then select Browse and select the desired tag from the localhost system or optionally a remote system for transfer over a network.

    Local: TagName.Value

    Remote: \\192.168.0.1\TagName.Value

    If OPC Item is selected select browse and select the OPC Server and Item

    If Azure IoT is selected then select the Driver Interface.

    If MQTT is selected then select the Driver Interface and Topic.

  6. Enter the desired float value Deadband field. Enter 0 for no deadband.
  7. If you want to specify a desired update frequency for the target check Write Continuously and enter the desired frequency. If Write Contentiously is unchecked the the target will be updated every time the source tag changes.
  8. Click the Apply Changes button to save your changes.
  9. Repeat this step for each tag that you want to transfer data from. This can also be done in bulk with CSV Import/Export or programatically.

For more detailed instructions on Configuring Data Route functionality, visit our Getting Started – Data Route tutorial or watch the videos below:

Multiple Tag Transfer

Tag to Tag Transfer

IoT Publish